Skip to content

Supported formats#

This page lists every file format NucleI reads and writes: vendor data you import, data and reports you export, the .nuclei files used to move projects between computers, and the results bundle written by a schedule.

Importing data#

Import from the Data Browser: the Import button offers Import Scan for one file or folder and Bulk Import for many. The File menu has the same two commands, Import Scan… (Ctrl+I) and Bulk Import Scans… (Ctrl+Shift+I). You can also drop files or folders onto the Data Browser or Acquisition page: one file opens Import Scan, and several files or a folder open Bulk Import.

The format is recognised from the file's contents, not only from its name. Each imported scan is saved and signed like a recorded one. A recognised T1 or T2 experiment is fitted for the T1 and T2 page.

Note

The file picker's NMR data filter shows only the common extensions (.dx, .jdx, .jcamp, fid, ser, 1r, 2rr, .ft, .ft2). For other formats in the table below, such as .jdf, .mnova, .nmrML or .txt, choose All Files in the picker, or pick the folder that contains the data.

Vendor and exchange formats#

Format What to select Dimensions and experiments Limits
Bruker TopSpin The experiment folder (the one holding acqus and fid or ser), or any file in it. 1D FID; 2D from ser, with the processed 2rr when present. Arrayed T1 (inversion recovery) and T2 (CPMG, spin echo) from vdlist; DOSY from difflist. Also reads the title, solvent, and TopSpin peak lists and integrals for 1D. A folder holding both a FID and processed data (pdata/…/1r or 2rr) offers a choice of Raw FID or Processed spectrum, in single and bulk imports; processed is the default. A processed spectrum keeps TopSpin's referencing, and TopSpin's phase is recorded as vendor values; time-domain steps do not apply to it. A folder with processed data only is imported as processed. Only 1D and 2D: 3D data is listed but refused.
Bruker WinNMR A .fid, .1r or .1i file with its .aqs beside it. 1D FID or processed spectrum. 1D only.
Bruker minispec A .sig file. 1D relaxation decay. Always treated as T1.
Varian / Agilent VnmrJ The .fid folder (holding fid and procpar). 1D and 2D FID. Arrayed parameters are kept as parameter lists. FID only; processed data in the folder is not read. 3D (ni2 above 1) is refused.
JEOL Delta A .jdf file. 1D and 2D, FID or spectrum. Only 1D and 2D.
Magritek Spinsolve The experiment folder (holding acqu.par and data.1d, spectrum.1d or a .2d file). 1D FID and spectrum; 2D such as COSY. With a delayTimes.txt the scan is treated as a T1 series. A T1 series needs data.1d.
Nanalysis NMReady The exported JCAMP-DX file. As JCAMP-DX below, including complex 1D, 2D (such as HSQC) and CPMG loop lists.
JCAMP-DX A .dx, .jdx or .jcamp file. 1D FID or spectrum (compressed or plain); complex 1D; 2D FID and spectrum as pages. Arrayed T1 and T2 detected from the parameters. Reads embedded Bruker and Varian parameters, Magritek and Nanalysis variants, and peak tables. One data block per file: in a linked file, only the block with data is imported.
NMRPipe A .fid, .ft, .ft1 or .ft2 file. 1D and 2D, FID or spectrum. Single-file data only. 3D files (.ft3) are refused with a message, never imported as a plane.
Chemagnetics Spinsight The folder holding acq and data. 1D FID and arrayed 2D FID. FID only.
SIMPSON A .fid or .spe file. 1D and 2D, FID or spectrum.
MestReC A .mrc file. 1D and 2D, FID or spectrum.
MestReNova A .mnova document. Every spectrum in the document: 1D and 2D, FID or processed. Each becomes a scan, all share one sample, and a document with several spectra is saved into one group named after the file (inside the chosen group, if any). The structures of the document become the sample's components, and the shifts it assigns to their atoms are kept as atom assignments. A spectrum is read only when its stated point counts account for its stored data exactly; otherwise it is listed as not imported. A processed spectrum is stored without its imaginary part. 1D peaks, multiplets with their couplings and integrals are recorded as imported from Mnova. 2D picked peaks are recorded the same way on their scan, with height, linewidths, Mnova's peak type (Artifact, Impurity, Compound, CS Reference, Quant. Reference) and the Diagonal flag; their volume is not stored in the document and is not imported. COSY, HSQC and HMBC correlations between assigned atoms become cross-peak assignments on the scan of that experiment. Page layout is not read, and drawings are listed for the page canvas; the import dialog lists what was imported and what was not.
nmrML A .nmrML file. 1D and 2D FID, and a 2D spectrum when present. Needs an FID.
NMReDATA An .sdf or .nmredata file. The structure, signals and assignments go into the sample. Spectra the record points to in local folders beside it are imported through their own formats. The first record only. Spectra given as web addresses are ignored.
RiDat A .RiDat file with its .Par.Txt beside it. 1D relaxation decay: CPMG (T2) or inversion recovery (T1).
Dmfit A .txt or .asc file with a ##freq line. 1D spectrum.
Text columns A .txt, .csv or .asc file of numbers. An optional evenly spaced axis column, then real and imaginary pairs. An axis that crosses zero is read as frequency, otherwise time. Several pairs make a 2D scan. No header lines allowed. No instrument metadata, so frequency and nucleus are unknown.

Problems found on import, such as a missing parameter or an unsupported acquisition mode, are listed under Warnings: in the import dialog.

Pulse program of imported scans#

The Sequence view of a scan's information shows the pulse sequence as the same timeline diagram as for a scan acquired with NucleI. Nothing is stored for it: the diagram is read from the program text kept with the scan each time it is opened, so signed and locked scans are unchanged.

  • Bruker TopSpin. The pulseprogram file of the experiment is read: delays, pulses on f1 to f3, shaped pulses, gradient pulses (p16:gp1), decoupling (cpd2:f2 to do:f2), continuous-wave irradiation, acquisition (go) and loops (lo to … times …, mc). Pulse widths, delays, loop counts and the acquisition time are resolved from the scan's P, D, CNST, L, IN, TD and SW_h and from the program's own assignments. A duration that cannot be resolved is shown as the program's expression, never as a number. The write-out delays of the mc macro are drawn as one delay, a loop that runs once is not drawn, and what follows go (data write, increments) is not drawn. An #include file the app does not carry is skipped and noted.
  • Incomplete diagrams. A statement the reader does not understand is not drawn; the diagram shows the rest, with a note listing the program lines left out. When nothing can be drawn the program source is shown as it is.
  • Varian / Agilent, JEOL and other formats. Varian sequences are compiled C and the other formats keep no program text, so the source text is shown as stored, without a diagram.

The same diagram is available in reports as {{experiment.sequence_diagram}}.

Bulk import#

Bulk Import searches the chosen folders for everything above and lists what it found before importing. The folder layout under the folder you chose becomes the scan's group. Hidden folders are skipped. The search stops at 12 folder levels, 2000 scans or 200,000 files, and says so.

Exporting scan data#

Right-click a scan in the Data Browser and choose Export scan…. Under Data to export choose FID, Spectrum or Both, then a format. Only the formats that can hold the scan are offered. With Both, two outputs are written, ending in _fid and _spectrum.

Format File Contents
CSV .csv A # header with title, solvent, reference, nucleus and frequency. 1D: columns for the time or frequency axis, real, imag, magnitude and phase (degrees). 2D: the magnitude matrix only.
NMRPipe .ft NMRPipe binary, 1D or 2D.
JCAMP-DX .dx JCAMP-DX 5.01 with compressed data; complex and 2D data as pages. A 2D export also writes the reference projections beside it.
Bruker TopSpin folder acqus, fid or ser, and pdata/1. Choose a parent folder; the scan's folder is created inside it.
NMReDATA .sdf NMReDATA 1.1: the structure, assignments and signals, with each experiment of the sample as a JCAMP-DX file beside it. Needs a structure (SMILES) in the sample. Spectrum only.
nmrML .nmrML Acquisition, FID, spectrum and assigned signals. 1H and 13C only, and needs the acquired FID. Spectrum only.
Nuclei file .nuclei The whole scan with its sample, analysis and project settings. See below.

Note

A Bruker export of a spectrum is refused while the spectrum still carries the digital-filter group delay; run group-delay correction first.

Project files (.nuclei)#

A .nuclei file carries a project, group, sample or scan to another computer, with its data, processing and settings. Export one from the Data Browser's right-click menu (Export project as .nuclei…, Export group as .nuclei…, Export sample as .nuclei…), from a scan's Export scan… menu, or with Export .nuclei in the sample overview.

Under Include in file: choose what goes in:

Item Default
Individual transients On
Peak edit history On
User and computer names in processing history Off
Instrument serial numbers Off
Report template On
Analysis code On for a whole project
Sequence and schedule Off

Sign with my key (on by default) lets recipients see that the file comes from you and has not been changed. On import, the dialog shows Signed by with a known or unknown key, Signature invalid: this file was altered, or Unsigned. Code in a project does not run until you trust it (see Security). Import a .nuclei file with Import Scan, by dropping it on the app, or by opening it from the operating system.

A lab pack is a .nuclei file whose project carries a teaching exercise. Students' progress is removed when the pack is exported, and the answer key stays sealed. See Teaching.

Saved items#

Sequences, analyses, schedules, processors and report templates can each be exported from their page's browser with Export to file… and brought back with Import from file…:

Item File
Sequence .nseq
Analysis .nanalysis
Schedule .nscd
Processor .nproc
Report template .nutemplate

The Report Builder can also import a Word document (.docx) as a template.

Structures can be imported and exported as MDL Molfile (.mol), SDF (.sdf), InChI and SMILES.

Reports#

The Report Builder generates reports as PDF Report, HTML Report or Word Document (DOCX). Generated reports are kept under Generated Reports, from which they can be downloaded again. The qNMR panel has its own Export PDF and Export HTML.

Tables#

Table Where Columns
1D peak table Download the table as CSV in the peak table group, group_shift_ppm, peak, shift_ppm, shift_hz, height, area, normalized_area, pattern, j_couplings_hz, linewidth_hz, linewidth_ppm, origin. Both units are exported, whichever is displayed.
2D peak table The same button on a 2D scan Both F2 and F1 positions in ppm and Hz, height, volume, pattern, couplings and line widths.
Integration regions Export CSV in the integration panel region, low_ppm, high_ppm, area, normalized_area.

The STD, series, DOSY, qNMR and QC panels have CSV exports of their own results.

Images#

  • Plots: the camera button in the plot's mode bar saves an image. Set its format (PNG, SVG, JPG or WebP), scale, width and height in the plot's Image Export Options. See Spectrum view.
  • Analysis figures: Download as PNG, SVG or PDF, or Add figure to report.
  • Report figures: size and resolution are set by Figure export size, Width (mm) and DPI in the Report Builder.
  • Structures: the shown structure can be saved as an SVG drawing.

Run results bundle#

The Export Results step in a Task Manager schedule writes one folder per run, for a LIMS or another program to pick up. The folder is named {date}_{time}_{sample}_{execution} by default (for example 20261113_091500_Sample-12_3f9a1c2e), never overwrites an existing one, and appears only once it is complete.

File Contents
result.json Always written. See below.
peaks.csv If Peak table (CSV) is ticked. 1D columns: peak_id, index, frequency_hz, frequency_ppm, height, area, normalized_area, linewidth_hz, multiplet_pattern, group_id. 2D columns: peak_id, frequency_f1_hz, frequency_f2_hz, frequency_f1_ppm, frequency_f2_ppm, height, volume, group_id.
report.pdf If Report (PDF) is ticked.

result.json has the schema nuclei.run-result, version 1. Every key is always present, and a value that is not known is null.

Key Contents
schema, schema_version "nuclei.run-result" and 1.
export_id, generated_at A unique id for this bundle and its time, in UTC.
software name and version.
run execution_id, schedule_id, schedule_name, entry_node_id, step_id, started_at, operator, and steps with each step's step_id, status and error.
project name.
sample id, name, description, solvent, compound_formula, molar_mass, user_data.
method sequence_name, experiment_type, nucleus, nucleus_f1, n_scans.
instrument device_type, provider, serial, display_name.
scan id, name, group, acquired_at, timestamp_offset_unknown, dimensions.
qc overall_pass, and records for the QC measurements made in this run.
peaks, shifts, integrals The scan's analysis results.
files Each file in the bundle with its SHA-256 and size, and references to files kept elsewhere, such as the stored scan and reports written earlier in the run.

If a webhook is set, the same result.json document is sent to it as an HTTP POST.