Skip to content

Acquisition#

The Acquisition page runs experiments and shows the result as it arrives. Pick a pulse sequence, set how the run is averaged, decide what happens to the data afterwards, and start.

The Acquisition page during a run

Running an experiment#

  1. Press Choose experiment… and choose a pulse sequence. The shipped sequences cover FID, Hahn-Echo, CPMG (plain and with decimation), stimulated echo, and T1 inversion recovery; anything you build on the Sequence page appears here too.
  2. Set Num. Scans — how many repetitions are averaged.
  3. Enable Phase Cycling for signal averaging that cancels systematic artefacts. The scan count must then be a multiple of four, and the field says so if it is not.
  4. Choose what happens after the run — see Saving the result.
  5. Press Start, or Shift+Enter. Both go through the same checks: a device must be connected and no other run active. When Start is disabled, hover it to see why.

Note

For a Python sequence, the scan count and phase cycling are owned by the script. The controls are disabled and say so rather than silently ignoring what you type.

Field Lock runs before the acquisition to stabilise the field. It sits with the run configuration rather than with the post-run options because that is when it happens.

The acquisition control panel

Watching the result#

The plot has three tabs: Signal for the time domain, Spectrum for the frequency domain, and History for the processing applied to the data so far.

Show split view adds a second plot beside or below the first, for comparing the running scan against one already recorded. Select the scan to compare from its picker, choose whether the panes stack vertically or sit side by side, and toggle whether the comparison scan is shown pre-processed or raw.

The plot itself is the shared spectrum view, so peak analysis, phase correction, qNMR, compound matching and the rest of the tool sidebar are available on a running result without leaving the page.

Saving the result#

The Result control decides what becomes of the data when the run finishes: save it as a new scan, overwrite the current scan, or don't save it at all. Choosing Override Current Scan asks you to confirm, naming the scan, and the run then replaces that scan's data instead of adding another. When the run finishes, the notification says which scan was saved and where, or that nothing was saved.

Save Snapshot saves the current data on demand rather than at the end of a run. It offers the same choice — save as a new scan, optionally named, or override the current one. A name only applies to a new scan.

Run Analysis executes the current analysis script against the acquired data. See Analysis.

A quality-control check can be attached to the run so that each result is judged as it arrives; it lives under More options in the compact layout.

Stopping a run#

Cancel asks for confirmation and shows how far the run got. Choose Stop and discard to drop the data acquired so far, or Stop and keep N scans to save them as a scan named with a "stopped" suffix. Keeping is offered only when the run saves its data; with phase cycling only whole cycles of four scans are kept. You cannot disconnect the device while a run is active.

Where the data goes#

Saved scans land in the current project, visible in the Data Browser. Set the project before a long run — a scan saved into the wrong project has to be moved by hand afterwards.